1,027 research outputs found

    Unusual superexchange pathways in a Ni triangular lattice of NiGa2_2S4_4 with negative charge-transfer energy

    Full text link
    We have studied the electronic structure of the Ni triangular lattice in NiGa2_2S4_4 using photoemission spectroscopy and subsequent model calculations. The cluster-model analysis of the Ni 2pp core-level spectrum shows that the S 3pp to Ni 3dd charge-transfer energy is \sim -1 eV and the ground state is dominated by the d9Ld^9L configuration (LL is a S 3pp hole). Cell perturbation analysis for the NiS2_2 triangular lattice indicates that the strong S 3pp hole character of the ground state provides the enhanced superexchange interaction between the third nearest neighbor sites.Comment: 10 pages, 5 figures, accepted to PR

    THz Wave Propagation on Strip Lines: Devices, Properties, and Applications

    Get PDF
    We report the propagation characteristics of THz pulses on micro-strip-lines and coplanar strip-lines, in which low permittivity polymer materials are used as the dielectric layer or the substrate. As a result of the low attenuation and small dispersion in the devices, the spectral width up to 3 THz can be achieved even after the 1 mm propagation. Spectroscopic characterizations of liquid or powder specimens are demonstrated using the devices. We also show a possibility of realizing a very low attenuation using a quadrupole mode in three strip coplanar lines on the polymer substrate

    SYNTAX II and SYNTAX III trials: What is the take home message for surgeons?

    Get PDF
    Percutaneous coronary intervention (PCI) has evolved greatly in the last 40 years since its introduction by Andreas Grüntzig in 1977. Since then, we've observed an evolution in balloons, the development of stents, changes in stent structure, development of drug eluting stents, improvements in strut design, thickness and even their polymeric coating. Most recently we saw the rise and "fall" of bioabsorbable scaffolds for PCI. Trials with the most diverse devices for PCI and diagnostic techniques have been conducted. Two of the most recent trials were reported in the last year and deserve special attention-SYNTAX II and SYNTAX III. These trials are completely different in design but present valuable information for doctors managing coronary artery disease (CAD). Both trials take into account contemporary technology for assessing and treating CAD. The first uses so-called "state-of-the-art" PCI and compares the outcomes of that approach with the outcomes of the PCI arm of the pivotal SYNTAX trial. SYNTAX III Revolution on the other hand does not focus on clinical endpoints: it is a blinded trial that does not randomize patients but randomizes doctors ("the heart team") to make a decision on the best treatment for complex CAD. This decision was based either on multi-slice CT with physiological assessment using FFRCT or on conventional angiography. In this review we bring the most important aspects of those trials and the key messages for surgeons together; also, what the surgeon may expect in the future after the publication of these interesting concepts

    Extracellular calcification of Braarudosphaera bigelowii deduced from electron microscopic observations of cell surface structure and elemental composition of pentaliths

    Get PDF
    We have performed morphological and crystallographic studies of Braarudosphaera bigelowii using various light and electron microscopy techniques. A study by light microscopy revealed that B. bigelowii has a haptonema, and can use it for adhesion to external substrates. A study of the pentaliths by transmission electron microscopy indicates that the well-known trapezoidal lamina is formed with foliate crystals having perfectly identical crystallographic orientation. A cytological study shows that the pentaliths of B. bigelowii are surrounded by an organic structure consisting of a pentalith-substrate and thin organic layers. The pentalith-substrate underlies the proximal surface of the pentaliths and extends between the sides of the individual pentaliths, it also extends between the five trapezoidal segments forming a pentalith. Thin organic layers, which apparently originate from ridges of pentalith-substrate, cover the distal surface of the trapezoidal segments. The close association between the pentalith-substrate, organic layers, and pentaliths leads us to the hypothesis that calcification of the pentaliths occurs between the pentalith-substrate and organic layers, extracellularly. The relatively high Mg content observed in pentaliths supports our hypothesis of extracellular calcification

    Successive phase transitions and phase diagrams of the quasi-two-dimensional triangular antiferromagnet Rb4Mn(MoO4)3

    Full text link
    Comprehensive experimental studies by magnetic, thermal and neutron measurements have clarified that Rb4Mn(MoO4)3 is a model system of a quasi-2D triangular Heisenberg antiferromagnet with an easy-axis anisotropy, exhibiting successive transitions across an intermediate collinear phase. As a rare case for geometrically frustrated magnetism, quantitative agreement between experiment and theory is found for complete, anisotropic phase diagrams as well as magnetic properties.Comment: 4 pages, 5 figure

    Bioresorbable scaffolds: a new paradigm in percutaneous coronary intervention

    Get PDF
    Numerous advances and innovative therapies have been introduced in interventional cardiology over the recent years, since the first introduction of balloon angioplasty, but bioresorbable scaffold is certainly one of the most exciting and attracting one. Despite the fact that the metallic drug-eluting stents have significantly diminished the re-stenosis ratio, they have considerable limitations including the hypersensitivity reaction to the polymer that can cause local inflammation, the risk of neo-atherosclerotic lesion formation which can lead to late stent failure as well as the fact that they may preclude surgical revascularization and distort vessel physiology. Bioresorbable scaffolds overcome these limitations as they have the ability to dissolve after providing temporary scaffolding which safeguards vessel patency. In this article we review the recent developments in the field and provide an overview of the devices and the evidence that support their efficacy in the treatment of CAD. Currently 3 devices are CE marked and in clinical use. Additional 24 companies are developing these kind of coronary devices. Most frequently used material is PLLA followed by magnesium

    Strut protrusion and shape impact on endothelial shear stress: insights from pre-clinical study comparing Mirage and Absorb bioresorbable scaffolds

    Get PDF
    Protrusion of scaffold struts is related with local coronary flow dynamics that can promote scaffold restenosis and thrombosis. That fact has prompted us to investigate in vivo the protrusion status of different types of scaffolds and their relationship with endothelial shear stress (ESS) distributions. Six Absorb everolimus-eluting Bioresorbable Vascular Scaffolds (Absorb, Abbott Vascular) and 11 Mirage sirolimus-eluting Bioresorbable Microfiber Scaffolds (Mirage, Manli Cardiology) were implanted in coronaries of eight mini pigs. Optical coherence tomography (OCT) was performed post-scaffold implantation and obtained images were fused with angiographic data to reconstruct the three dimensional coronary anatomy. Blood flow simulation was performed and ESS distribution was estimated for each scaffold. Protrusion distance was estimated using a dedicated software. Correlation between OCT-derived protrusion and ESS distribution was assessed for both scaffold groups. A significant difference was observed in the protrusion distances (156 ± 137 µm for Absorb, 139 ± 153 µm for Mirage; p = 0.035), whereas difference remained after adjusting the protrusion distances according to the luminal areas. Strut protrusion of Absorb is inversely correlated with ESS (r = -0.369, p < 0.0001), whereas in Mirage protrusion was positively correlated with EES (r = 0.192, p < 0.0001). Protrusion distance was higher in Absorb than in Mirage. The protrusion of the thick quadratic struts of Absorb has a tendency to lower shear stress in the close vicinity of struts. However, circular shape of the less thick struts of Mirage didn't show this trend in creating zone of recirculation around the struts. Strut geometry has different effect on the relationship between protrusion and shear stress in Absorb and Mirage scaffolds
    corecore